Search results for "pressure [gas]"
showing 9 items of 99 documents
Low energy calibration, continuous monitoring, and background studies for the NEXT-White detector at the LSC
2021
Los neutrinos han sido una puerta a grandes cambios en los paradigmas del entendimiento de la naturaleza, y aún tienen preguntas que responder en las próximas décadas. El descubrimiento de la oscilación de neutrinos implica que éstos son partículas con masa. Esta masa abre la cuestión de su origen, es decir, si son fermiones de Dirac o de Majorana. La potencial naturaleza de Majorana puede arrojar luz en temas abiertos como la baja escala de masas de los neutrinos con respecto a los demás fermiones, así como la asimetría entre materia y antimateria observada actualmente en el universo. De entre todas las posibles formas de discernir la naturaleza última de los neutrinos, la más madura y des…
H2O-content and temperature limit the explosive potential of rhyolite magma during Plinian eruptions
2019
Abstract Recent rhyolite eruptions on Earth have demonstrated their capacity to produce a multitude of hazards, including ash formation lasting months and impacting the large reaches of the southern hemisphere. Nevertheless, the underlying mechanisms driving these eruptions are not yet fully understood. Magmatic volatiles, especially H2O, dictate whether volcanic eruptions proceed explosively or effusively. Experimental evidence for the role played by H2O in driving explosive fragmentation is rare, in particular in the eruption of rhyolitic magma. Here we show that when hydrous rhyolitic obsidians from Chaiten Volcano (Chile) are experimentally heated above their glass transition temperatur…
Blood-pressure variability in patients with obstructive sleep apnea: current perspectives
2018
Obstructive sleep apnea (OSA) is often associated with hypertension and other cardiovascular diseases. Blood pressure (BP) variability is part of the assessment of cardiovascular risk. In OSA, BP variability has been studied mainly as very short-term (beat-by-beat) and short-term (24-hour BP profile) variability. BP measured on consecutive heartbeats has been demonstrated to be highly variable, due to repeated peaks during sleep, so that an accurate assessment of nocturnal BP levels in OSA may require peculiar methodologies. In 24-hour recordings, BP frequently features a "nondipping" profile, ie, <10% fall from day to night, which may increase cardiovascular risk and occurrence of major…
Computational fluid dynamics simulation to evaluate aortic coarctation gradient with contrast-enhanced CT
2014
Coarctation of aorta (CoA) is a narrowing of the aorta leading to a pressure gradient (Delta P) across the coarctation, increased afterload and reduced peripheral perfusion pressures. Indication to invasive treatment is based on values of maximal (systolic) trans-coarctation Delta P. A computational fluid dynamic (CFD) approach is herein presented for the non-invasive haemodynamic assessment of Delta P across CoA. Patient-specific CFD simulations were created from contrast-enhanced computed tomography (CT) and appropriate flow boundary conditions. Computed Delta P was validated with invasive intravascular trans-CoA pressure measurements. Haemodynamic indices, including pressure loss coeffic…
From Clinical Imaging to Patient-Specific Computational Model: Rapid Adaptation of the Living Heart Human Model to a Case of Aortic Stenosis
2021
Aortic stenosis (AS) is the most common acquired heart valve disease in the developed world. Traditional methods of grading AS have relied on the measurement of aortic valve area and transvalvular pressure gradient. Recent research has highlighted the existence of AS variants that do not meet classic criteria for severe AS such as low-flow, low-gradient AS. With the development of sophisticated multi-scale computational models, investigation into the left ventricular (LV) biomechanics of AS offers new insights into the pathophysiology that may guide treatment decisions surrounding AS. Building upon our prior study entailing LV-aortic coupling where AS conditions were applied to the idealize…
Translation and testing of the Risk Assessment Pressure Ulcer Sore scale used among residents in Norwegian nursing homes.
2012
Published version of an article in the journal: BMJ Open. Also available from the publisher at: http://dx.doi.org/10.1136/bmjopen-2012-001575 Open access Objective. The purpose of this study was to translate and test the psychometric properties of the Norwegian-language version of the Risk Assessment Pressure Sore scale. Background. Risk assessment scales for pressure ulcer prevention have become an aspect of quality improvement in healthcare, but their effectiveness depends on the reliability and validity of the scale. Methods. A convenience sample of 481 residents in 15 nursing homes in rural Norway was included between January and June 2007. The English-language version of the Risk Asses…
Sigh in patients with acute hypoxemic respiratory failure and acute respiratory distress syndrome: the PROTECTION pilot randomized clinical trial
2021
Background: Sigh is a cyclic brief recruitment manoeuvre: previous physiological studies showed that its use could be an interesting addition to pressure support ventilation to improve lung elastance, decrease regional heterogeneity and increase release of surfactant. Research question: Is the clinical application of sigh during pressure support ventilation (PSV) feasible? Study design and methods: We conducted a multi-center non-inferiority randomized clinical trial on adult intubated patients with acute hypoxemic respiratory failure or acute respiratory distress syndrome undergoing PSV. Patients were randomized to the No Sigh group and treated by PSV alone, or to the Sigh group, treated b…
Pressure support ventilation + sigh in acute hypoxemic respiratory failure patients: Study protocol for a pilot randomized controlled trial, the PROT…
2018
Background Adding cyclic short sustained inflations (sigh) to assisted ventilation yields optimizes lung recruitment, decreases heterogeneity and reduces inspiratory effort in patients with acute hypoxemic respiratory failure (AHRF). These findings suggest that adding sigh to pressure support ventilation (PSV) might decrease the risk of lung injury, shorten weaning and improve clinical outcomes. Thus, we conceived a pilot trial to test the feasibility of adding sigh to PSV (the PROTECTION study). Methods PROTECTION is an international randomized controlled trial that will be conducted in 23 intensive care units (ICUs). Patients with AHRF who have been intubated from 24 h to 7 days and under…
Parametric sensitivity of a CFD model concerning the hydrodynamics of trickle-bed reactor (TBR)
2016
Abstract The aim of the present study was to investigate the sensitivity of a multiphase Eulerian CFD model with respect to relations defining drag forces between phases. The mean relative error as well as standard deviation of experimental and computed values of pressure gradient and average liquid holdup were used as validation criteria of the model. Comparative basis for simulations was our own data-base obtained in experiments carried out in a TBR operating at a co-current downward gas and liquid flow. Estimated errors showed that the classical equations of Attou et al. (1999) defining the friction factors Fjk approximate experimental values of hydrodynamic parameters with the best agre…